SV660N + MS1 from Scratch: EtherCAT, ROS 2, and a Smooth First Spin
Published:
Complete desk path from a fresh Ubuntu machine plus an Inovance SV660N drive and MS1 motor to a smooth first spin. Everything needed to succeed is in this post—commands, wiring, panel reading, and the mistakes that cost days on this desk.
- What you will achieve
- Hardware this guide assumes
- Safety
- 1. Bill of materials (beyond PC)
- 2. Hardware wiring checklist
- 3. Panel literacy (enough to spin)
- 4. OS: Ubuntu 24.04 + realtime kernel
- 5. ROS 2 Jazzy and build tools
- 6. IgH EtherCAT master (–disable-eoe required)
- 7. Workspace (stacker + Inovance configs)
- 8. Every boot / every session checklist
- 9. First enable (no motion yet)
- 10. What CSP means (read before spinning)
- 11. First smooth spin (CSP)
- 12. Stop cleanly
- 13. Troubleshooting
- 14. Appendix
- Further reading (optional)
What you will achieve
| Step | Target |
|---|---|
| Idle bus | Panel _28ry, ethercat slaves → PREOP |
| Enabled CSP | Panel _88rn, 0x6041 ≈ 0x1637, 0x6061 = 8 |
| Motion | Soft CSP stream; shaft turns smoothly (no stair-steps / E6200) |
| Stop | Ctrl+C → PREOP, 0x603F = 0, no EE081 |
Keep Sync0 / ros2_control at 100 Hz (10 ms). Do not “upgrade” to 1 ms until you understand Write-cycle budget.
Hardware this guide assumes
| Role | Exact model (this desk) |
|---|---|
| Drive | SV660NS2R8I |
| Motor | MS1H4-40B30CBA334R (brake variant — last digit family 4) |
| Encoder | Absolute, 23-bit → 8388608 counts / rev |
| Bus | Dedicated Ethernet NIC → IgH master → drive EtherCAT IN |
| Host | Ubuntu 24.04, PREEMPT_RT kernel, ROS 2 Jazzy |
| Software | Stacker codes/ros2_ws with Inovance YAML + mode:=csp\|csv\|pp (not bare upstream ICube alone) |
Software path used below:
# Desk machine often uses /work/stacker — elsewhere clone/checkout as ~/stacker
export STACKER=/work/stacker # or: export STACKER=$HOME/stacker
export WS=$STACKER/codes/ros2_ws
Safety
- Mount the motor horizontal, bare shaft clear. Keep hands/tools away once enabled.
- If STO / E-stop is wired, know how to cut power.
- After E6200 / E6400: stop motion, cool ≥ 30–60 s, reset once. Do not spam H0d.01.
- Prefer Ctrl+C on the launch terminal. Avoid
kill -9onros2_control_nodewhile the drive is in OP + enabled (latches EE081). - Desk brake unlock = external 24 V always on is OK for a horizontal axis. For a vertical axis you need timed BK via relay / drive DO so the shaft does not drop when disabled.
1. Bill of materials (beyond PC)
| Item | Notes |
|---|---|
| SV660N drive + mains cable | Rated for motor; PE connected |
| MS1 motor + power + encoder cables | Use brake power cable if motor has BK leads |
| EtherCAT patch cable | Master NIC → drive CN3 (IN) |
| Dedicated Ethernet NIC | Prefer a second NIC so LAN and EtherCAT are not the same port |
| 24 VDC PSU for holding brake | See next subsection — mandatory on this motor |
Holding brake electrical (do not skip)
This MS1 is a brake motor. BK+/BK− unpowered = shaft mechanically locked. Commanding CSP/CSV/PP against a locked brake looks like “stairs,” huge torque (0x6077), then E6200. Desk confirmation: after 24 V on the brake, CSP / CSV / PP all spin smoothly.
| Spec (MS1H4-40B30CB-A33*R) | Value |
|---|---|
| Supply | 24 VDC ±10% |
| Exciting current | 0.32 A |
| Rated power | 7.6 W |
| Coil resistance | ~75.8 Ω ±7% |
| Holding torque | 1.5 N·m |
| Release / apply | ≤ 20 ms / ≤ 60 ms |
Desk PSU: 24 V, ≥ 0.5 A, preferably dedicated to the brake; cable ≥ 0.5 mm². Coil has no polarity.
- Desk validation: connect external 24 V directly to motor BK+ / BK− (always released while powered).
- Production: 24 V through a relay whose coil is driven by the drive’s BK digital output (drive DO is a weak signal — it does not replace the 24 V supply).
Datasheet sources: MS1-R INT selection guide (EN) (section MS1H4-40B30CB-A33*R-INT), older MS1 guide data code 19010786 §1.3.5.
Verify before any ROS motion: apply 24 V → hear/feel brake release click; with servo off you should not feel a hard lock (horizontal desk).
2. Hardware wiring checklist
Mains AC ──► SV660N (L/N/PE per label)
│
├── U/V/W/PE ──► MS1 motor power
├── CN2 ────────► encoder cable
├── CN3 IN ◄──── EtherCAT NIC (master)
└── CN4 OUT (unused on single-axis desk)
External 24 VDC ──► motor BK+ / BK− ← REQUIRED on …A334R
| Connection | Check |
|---|---|
| Mains + PE | Drive powers; keypad alive |
| Motor power | Phase order per cable; PE on |
| Encoder | CN2 seated; no bent pins |
| EtherCAT | PC → CN3 IN only (not OUT) |
| Brake 24 V | BK+/BK− powered; release click |
Power the drive. Until the PC master is up you may see Init/ready-style glyphs; after IgH Idle + cable you want _28ry-class idle (see panel section).
3. Panel literacy (enough to spin)
Five LEDs are one composite status (not five unrelated screens):
LED: [ 1st ] [ 2nd ] [ 3rd ] [ 4th ] [ 5th ]
field: link AL mode ---- servo ----
ex.: _ 2 8 r y → _28ry
| Position | Meaning |
|---|---|
| 1st | PHY link segments (can look blank) |
| 2nd | EtherCAT AL: 1 Init, 2 PREOP, 4 SAFEOP, 8 OP |
| 3rd | Mode: 8 CSP, 9 CSV, 1 PP |
| 4th–5th | ry ready / rn running (enabled) |
| You want | Meaning |
|---|---|
_28ry | PREOP + CSP mode digit + ready — idle master OK |
_88rn | OP + CSP + enabled — ready for CSP demos |
_89rn | OP + CSV + enabled |
_81rn | OP + PP + enabled |
AL blink: PREOP’s 2 blinks ~400 ms — normal. Fault is all five digits blinking with E… / EE….
| Panel (as read) | Meaning | Typical CoE | What to do |
|---|---|---|---|
| E6200 | Motor overload (I²t) | 0x603F=0x3230 | Stop, cool ≥30–60 s, reset once |
| E6400 | IGBT over-temp | — | Stop, cool; do not re-enable hot |
| EE081 | Network status switchover | 0x0E08 | Usually kill-in-OP; cool, H0d.01 once → want 28ry |
| EE150 | Excessive sync period | 0x0E15 | Sync0/jitter; stay at 100 Hz; fix RT later |
Keypad clear (when cool): SET → H0d.01 = 1 (alarm reset). One shot.
Cross-check from PC (after IgH is installed):
ethercat slaves
ethercat upload -p0 0x6041 0 --type uint16 # statusword
ethercat upload -p0 0x603F 0 --type uint16 # error code (0 = ok)
ethercat upload -p0 0x6061 0 --type int8 # mode display
Healthy OP + enabled CSP example: slaves OP +, 0x6041≈0x1637, 0x603F=0, 0x6061=8.
4. OS: Ubuntu 24.04 + realtime kernel
- Install Ubuntu 24.04 LTS (Noble).
- Install the realtime kernel:
sudo apt update
sudo apt install -y ubuntu-realtime
sudo reboot
- Confirm:
uname -r
# must contain: realtime
NVIDIA dual-GPU note (only if apt breaks)
On Intel + NVIDIA laptops, ubuntu-realtime often fails when DKMS tries to build proprietary NVIDIA modules against PREEMPT_RT. If dpkg is broken after that:
- Do not interrupt a long “2%” header extract — wait.
- After a NVIDIA DKMS failure: finish/fix
dpkg, keep using the realtime kernel for EtherCAT; restore NVIDIA only on the generic kernel if you need the discrete GPU for other work.
(Longer NVIDIA/DKMS write-up: sibling post on this site about Ubuntu 24.04 PREEMPT_RT + dual GPU — optional.)
Optional: isolate CPUs for the control thread
Not required for a first 100 Hz spin, but recommended on this desk:
sudo nano /etc/default/grub
# append to GRUB_CMDLINE_LINUX_DEFAULT:
# isolcpus=2,3 nohz_full=2,3 rcu_nocbs=2,3
sudo update-grub
sudo reboot
cat /proc/cmdline | grep isolcpus
5. ROS 2 Jazzy and build tools
Use system Python for ROS (which python3 should not be inside a project venv that shadows ros2).
sudo curl -sSL https://raw.githubusercontent.com/ros/rosdistro/master/ros.key \
-o /usr/share/keyrings/ros-archive-keyring.gpg
echo "deb [arch=$(dpkg --print-architecture) signed-by=/usr/share/keyrings/ros-archive-keyring.gpg] http://packages.ros.org/ros2/ubuntu $(. /etc/os-release && echo $UBUNTU_CODENAME) main" \
| sudo tee /etc/apt/sources.list.d/ros2.list > /dev/null
sudo apt update
sudo apt install -y \
build-essential cmake git pkg-config autoconf libtool \
python3-pip python3-dev \
python3-colcon-common-extensions python3-rosdep python3-vcstool \
net-tools ethtool \
ros-jazzy-desktop \
ros-jazzy-ros2-control \
ros-jazzy-ros2-controllers \
ros-jazzy-hardware-interface \
ros-jazzy-xacro
sudo rosdep init # ok if it says already initialized
rosdep update
echo "source /opt/ros/jazzy/setup.bash" >> ~/.bashrc
source ~/.bashrc
ros2 --help | head
6. IgH EtherCAT master (–disable-eoe required)
SV660 CoE breaks if IgH is built with EoE (mailbox contention). Always configure with --disable-eoe.
Dependencies
sudo apt install -y dkms linux-headers-$(uname -r)
Build and install
cd ~
git clone https://gitlab.com/etherlab.org/ethercat.git
cd ethercat
./bootstrap
./configure --sysconfdir=/etc --disable-8139too --enable-generic --disable-eoe
make -j$(nproc)
make -j$(nproc) modules # required — otherwise ec_master missing
sudo make modules_install install
sudo depmod -a
Bind a NIC and permissions
Pick the EtherCAT interface (ip link), not your LAN if you have two NICs:
ip -br link
ETH_IFACE="eno1" # <-- replace with your EtherCAT NIC
sudo cp -n /etc/sysconfig/ethercat /etc/sysconfig/ethercat.bak
sudo sed -i "s/MASTER0_DEVICE=\"\"/MASTER0_DEVICE=\"$ETH_IFACE\"/" /etc/sysconfig/ethercat
sudo sed -i 's/DEVICE_MODULES=""/DEVICE_MODULES="generic"/' /etc/sysconfig/ethercat
sudo tee /etc/udev/rules.d/99-EtherCAT.rules <<'EOF'
KERNEL=="EtherCAT[0-9]*", MODE="0666"
EOF
sudo udevadm control --reload-rules
sudo udevadm trigger
sudo /etc/init.d/ethercat start
ls -l /dev/EtherCAT0 # want crw-rw-rw-
ethercat slaves
# 0 0:0 PREOP + SV660_1Axis_...
Identity check:
ethercat slaves -v | head -40
# Vendor Id: 0x00100000
# Product code: 0x000c010d
Realtime privileges for ros2_control (FIFO)
Without this, launch may warn Could not enable FIFO RT scheduling policy and at higher rates spawners time out even though the drive reaches OP.
# Replace YOUR_USER with your Linux login name
sudo tee /etc/security/limits.d/99-realtime-ros.conf <<EOF
YOUR_USER - rtprio 99
YOUR_USER - nice -20
YOUR_USER - memlock unlimited
EOF
Log out and back in (new session). Then:
ulimit -r # must be 99
Do not setcap cap_sys_nice=ep on ros2_control_node — that breaks LD_LIBRARY_PATH and the node exits 127.
One NIC for both Internet and EtherCAT
When you need apt/Internet on the same port:
sudo /etc/init.d/ethercat stop
sudo rmmod ec_generic ec_master 2>/dev/null || true
sudo systemctl restart NetworkManager
Back to motor work:
sudo /etc/init.d/ethercat start
7. Workspace (stacker + Inovance configs)
Upstream ICube examples alone do not ship this desk’s Inovance slave YAML / mode:=csp|csv|pp launch. Use the stacker tree whose 3rd-party holds the patched driver + ethercat_motor_drive.
export STACKER=/work/stacker # or $HOME/stacker
export WS=$STACKER/codes/ros2_ws
cd "$WS"
# If 3rd-party clones are missing:
# mkdir -p 3rd-party && cd 3rd-party
# git clone https://github.com/ICube-Robotics/ethercat_driver_ros2.git
# git clone https://github.com/ICube-Robotics/ethercat_driver_ros2_examples.git
# then ensure inovance_sv660_*.yaml + mode:= launch presets are present
# (stacker desk already has them under 3rd-party/...).
# Use system ROS Python
source /opt/ros/jazzy/setup.bash
which python3
cd "$WS"
rosdep install --from-paths 3rd-party --ignore-src -r -y
colcon build --symlink-install --base-paths 3rd-party
source "$WS/install/setup.bash"
Why these patches matter:
- Inovance PDO / mode YAML (
inovance_sv660_config.yaml,_csv,_pp) - Launch
mode:=csp|csv|pp - Safe Ctrl+C: disable CiA402 while still OP, then PREOP (avoids EE081)
- PP: control-word override during shutdown so ForwardCommandController cannot keep enable bits
Confirm scripts are executable:
ls "$WS/scripts"/spin_bare_motor_demo*.sh "$WS/scripts"/stop_motor_drive.sh
8. Every boot / every session checklist
# Brake 24 V ON (release click)
# Panel clear of E… / EE… (or cool + one H0d.01)
echo performance | sudo tee /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor
cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_governor # performance
sudo /etc/init.d/ethercat status
# or: sudo /etc/init.d/ethercat start
bash "$WS/scripts/check_ethercat_link.sh" # if present
ethercat slaves # PREOP +
# Panel: _28ry
ulimit -r # 99 — if 0, new login after limits.d
Stay at 100 Hz control / Sync0 for beginners.
9. First enable (no motion yet)
Terminal 1 (login shell with RT limits):
export STACKER=/work/stacker
export WS=$STACKER/codes/ros2_ws
ulimit -r
cd "$WS"
source /opt/ros/jazzy/setup.bash
source install/setup.bash
# If master already claimed:
# bash scripts/stop_motor_drive.sh
ros2 launch ethercat_motor_drive motor_drive.launch.py
# equivalent: mode:=csp
Expect log lines like Operation Enabled / controllers activated, and ideally:
Successful set up FIFO RT scheduling policy with priority 50
Checks:
# other terminal
source /opt/ros/jazzy/setup.bash
source "$WS/install/setup.bash"
ethercat slaves # OP +
ethercat upload -p0 0x6061 0 --type int8 # 8
ethercat upload -p0 0x6041 0 --type uint16
ethercat upload -p0 0x603F 0 --type uint16 # 0
ros2 control list_controllers
ps -o pid,cls,rtprio,comm -C ros2_control_node # CLS=FF, RTPRIO~50 preferred
Panel target: _88rn.
Optional pin to isolated CPUs (if you set isolcpus=2,3):
PID=$(pgrep -n ros2_control_node)
sudo taskset -cp 2,3 "$PID"
If OP but controllers never activate / no motion later: fix ulimit -r / re-login first; keep 100 Hz.
10. What CSP means (read before spinning)
CSP (mode 8) = every cycle the master sends a target position (0x607A). The drive tracks; it does not invent a trajectory.
demo script ~100 Hz
→ /forward_position_controller/commands
→ RxPDO 0x607A (counts)
→ SV660 position loop
→ motor
Publishing one target far from actual is still “valid CSP” — the drive chases ASAP → whip / E6200. Always use a streamed soft path (the demo scripts).
Units: encoder counts. One revolution = 8388608 counts.
11. First smooth spin (CSP)
With launch still running and panel _88rn:
source /opt/ros/jazzy/setup.bash
source "$WS/install/setup.bash"
# Recommended first motion: smooth +360° quintic (no reverse)
bash "$WS/scripts/spin_bare_motor_demo3_smooth_360.sh"
Shaft should turn continuously and smoothly. If you hear stair-steps or trip E6200 immediately:
- Confirm brake 24 V is really on (most common miss).
- Stop launch, cool, clear fault once, retry soft.
Other CSP scripts (after demo3 works):
bash "$WS/scripts/spin_bare_motor_demo2_smooth_profile_position.sh"
# demo1 is harsher — not for first spin
Optional: CSV (velocity)
# stop CSP launch first (Ctrl+C), then:
ros2 launch ethercat_motor_drive motor_drive.launch.py mode:=csv
# panel ~ _89rn when enabled
bash "$WS/scripts/spin_bare_motor_demo4_csv.sh 5 1 # soft: 5 rpm × 1 s
Optional: PP (profile position)
ros2 launch ethercat_motor_drive motor_drive.launch.py mode:=pp
# panel ~ _81rn
bash "$WS/scripts/spin_bare_motor_demo5_pp.sh 30 # +30° internal profile
PDO map is fixed at activate — restart launch to change mode.
12. Stop cleanly
In the launch terminal: Ctrl+C.
Or:
bash "$WS/scripts/stop_motor_drive.sh"
Expect: slave PREOP, panel ready-class _28ry, 0x603F=0. Patched driver disables CiA402 before AL exit so EE081 should not latch.
Avoid kill -9 while enabled in OP.
13. Troubleshooting
| Symptom | Likely cause | Fix |
|---|---|---|
Permission denied on /dev/EtherCAT0 | udev / perms | udev rule above; ls -l → 666; restart master |
ec_master not found | modules not built/installed | make modules + modules_install + depmod on this kernel |
| Mailbox / EoE weirdness | IgH built with EoE | Rebuild with --disable-eoe |
| PREOP OK, launch dies / no OP | Wrong vendor YAML, cable on OUT, WD/DC | Cable on CN3 IN; use Inovance YAML; read launch log |
| OP + enabled, no motion | FIFO denied / controllers not active | ulimit -r=99, re-login; list_controllers |
| Stairs sound + E6200 | Brake 24 V missing | Power BK+/BK−; verify release click |
| EE081 after stop | Hard kill / CW held in PP | Ctrl+C / stop script; cool; one H0d.01 |
| EE150 | Sync period bad | Stay 100 Hz; improve RT later |
| E6200 after “OK” move | I²t / hunting / prior heat | Cool ≥30–60 s; one reset; softer next move |
| Fault reset → shaft jumps | CSP catch-up (607A≠6064) | Realign / deactivate forward before reset; see CiA402 notes |
setcap → exit 127 | Broken loader path | Remove setcap; use limits.d only |
Manual fault clear
Panel SET → H0d.01 = 1 (once, when cool)
ROS rising-edge reset (launch up, after cool) uses reset_fault_controller — only after you understand catch-up risk; prefer panel clear + relaunch for day one.
14. Appendix
Glossary
EtherCAT / CoE
| Abbr | Expansion |
|---|---|
| IgH | IgH EtherCAT Master (this desk’s master stack; /dev/EtherCAT0, ethercat CLI) |
| ESI | EtherCAT Slave Information (XML describing the drive) |
| AL | Application Layer state: INIT → PREOP → SAFEOP → OP |
| OP | Operational — cyclic PDO running |
| DC | Distributed Clocks — shared time base for slaves |
| Sync0 | DC latch / interrupt; rate at which cyclic PDO is taken |
| SM / SM2 | Sync Manager; SM2 = RxPDO channel (watchdog on SV660N) |
| PDO | Process Data Object — cyclic process data every Sync0 |
| RxPDO | Receive PDO — master → drive (commands) |
| TxPDO | Transmit PDO — drive → master (feedback) |
| SDO | Service Data Object — slow mailbox (config, fault code, mode) |
| CoE | CANopen over EtherCAT |
| EoE | Ethernet over EtherCAT (do not mix with CoE mailbox on SV660 — build IgH with --disable-eoe) |
| WD | Watchdog (SM2 expects cyclic RxPDO) |
| WC | Working counter (how many slaves answered the cyclic frame) |
CiA402 / servo
| Abbr | Expansion |
|---|---|
| CiA402 | CANopen drive profile (state machine + 0x60xx objects) |
| CSP | Cyclic Synchronous Position (mode 8) — master streams 0x607A |
| CSV | Cyclic Synchronous Velocity (mode 9) |
| CST | Cyclic Synchronous Torque (mode 10) |
| PP | Profile Position (mode 1) — drive ramps to one target |
| HM | Homing mode |
| CW / SW | Controlword 0x6040 / Statusword 0x6041 |
| I²t | Accumulative thermal/current model (panel E6200 = E620.0) |
Common objects on this axis: 0x607A target position, 0x6064 actual position (encoder counts, MS1 ≈ 2²³ / rev), 0x6060/0x6061 mode, 0x603F error code.
ROS 2 / this stack
| Abbr | Expansion |
|---|---|
| CM | ros2_control controller_manager (ros2_control_node) |
| JTC | joint_trajectory_controller |
| FIFO / RT | SCHED_FIFO realtime scheduling (kernel PREEMPT_RT ≠ process is FIFO) |
| DDS | ROS 2 middleware (topics; not the EtherCAT cycle) |
Panel
Keypad glyphs (_88rn, E6200, EE081, …) are summarized in Panel literacy above; full map: SV660N keypad panel status codes.
CoE cheat sheet
| Object | Name |
|---|---|
0x6040 | Controlword |
0x6041 | Statusword |
0x6060 / 0x6061 | Mode / mode display |
0x607A | Target position |
0x6064 | Position actual |
0x60FF | Target velocity (CSV) |
0x603F | Error code |
0x6077 | Torque actual (scaled) |
Success checklist (print this)
- Brake 24 V on
uname -rhas realtime- IgH
--disable-eoe,ethercat slaves→ PREOP ulimit -r→ 99- Launch CSP → panel
_88rn demo3smooth spin- Ctrl+C → PREOP,
0x603F=0
Further reading (optional)
These are not required if you followed this post: